Roots Blower在使用的过程中出现了超负荷和正常负荷,那么超负荷和正常负荷是如何运转的呢?小编带您了解一下。一 鼓风机空负荷试运转。
(1) Newly installed or overhauled fans should undergo an empty load test run.
(2) The concept of Roots blower no-load operation: put into operation under the condition that the inlet and outlet valves are all open.
(3) test run should pay attention to observe the lubricant splash situation is normal, such as too much or too little should be adjusted oil.
(4) There is no abnormal odor or smoke phenomenon and collision or friction sound, the radial amplitude of the bearing parts is not more than 0.08mm.
(5) No-load operation for about 30 minutes, such as the situation is normal that is put into operation with load. If found that the operation is not normal should be immediately checked, troubleshooting still need to be empty load operation.
II Normal blower operation with load
(1) Adjust gradually and slowly as required to bring the load up to the rated load. It is not allowed to adjust to the rated load at one time.
(2) The so-called rated load refers to the static pressure difference between the intake and exhaust ports as indicated on the nameplate. If the pressure at the exhaust port is normal, attention must be paid to the pressure change at the intake port to avoid overloading.
3) Due to the characteristics of the Roots blower, it is not permitted to return the gas from the exhaust port directly into the air inlet of the blower for a long period of time, otherwise the safety of the machine will be affected.
(4) fan normal work, it is strictly prohibited to completely close the air inlet and outlet hear valve, also not allowed to overload operation.
(5) blower rated operating conditions, the surface temperature of the rolling bearings generally does not exceed 85 ℃, the oil temperature of the lubricating oil in the oil tank does not generally exceed 65 ℃, near the bearing parts of the radial vibration does not exceed 0.08mm.
6) Always pay attention to the splash condition of the lubricant and the position of the oil level.